HP-1150 Toner Cartridges
DOC-0319
In March 2003, Hewlett Packard released the LaserJet
1150 printer. It was released in Europe and Asia, but not in North America.
The HP-1150 series of laser printers is based on 17 ppm, 1200dpi Canon engine.
From what limited information is available, the 1150 machines are slated to be
released in North America, but no date has been set. The good news is that it
does not have a chip! There is not even a location for one! The Q2624A
is rated for 2,500 pages. The cartridges are almost identical to the 1200, and
use some of the same supplies. The Wiper Blade and Dr. Blades are identical to
the HP-1200. The Toner is NOT! It has a different melt point. The Drum,
Magnetic Roller, and PCR we are not sure about. They appear to be physically
the same as HP-1200, but, we cannot be sure until all the tests are in.
Hopefully by the time you are reading this, all that will be resolved. The
1150 is the third generation cartridge of the HP-1200. Figures A-B show the
only physical cosmetic cartridge difference between the HP-1200, and 1150.
Basically the two differences are that the 1150 is a gray cartridge, and that
it has a fin on the top left side. We are not yet able to determine
compatibilities between an 1150 machine and the 1200 as we do not yet have a
machine here. (I.E. does the fin actuate a switch or not). As soon as the
machine is released here, we will have more information.
FIGURE A |
FIGURE B |
The 1150 machine replaces (or will replace) the HP-1000 series as a low cost
machine. The low cost approach may be why there is no chip. (Although the EU
WEEE directive may have also had something to do with it.)
The pin system holding the two halves of the cartridge
together is similar to the HP-1200. You will need to cut two small holes cut
in the top to get access to the pins. The hole location on these cartridges is
almost identical to the 1200, and the same methods you use for the 1200 should
work here.
Cartridge troubleshooting as well as running test
pages, cleaning pages and some simple printer troubleshooting will be covered
at the end of this article.
-
Phillips head screw driver.
-
Small Common screw driver
-
Dremel type tool with side grinding bit
-
150g HP-1150 toner, (Not HP-1200!)for the Q2624A
cartridge (2500 pages)
-
New Drum (Possibly an HP-1200 cannot tell
with out running tests)
-
Wiper Blade (HP-1200)
-
Dr. Blade (HP-1200)
-
Magnetic roller (Possibly an HP-1200 cannot
tell with out running tests)
-
Sealing Strip
-
Cotton Swabs
-
Isopropyl Alcohol
-
Drum Padding Powder
-
Conductive Grease
The pins in these cartridges are very similar to the
HP-1200 cartridge. The best way to remove them without damaging the cartridge
is to cut two small holes in basically the same area as the 1200.
-
Remove the drum cover by prying up on each end.
Note how the spring position so that you it can be replaced later. See
Figures 1 & 2
-
Drill a shallow hole on each side of the cartridge
as indicated by figures 3 & 4.
FIGURE 1
|
FIGURE 2
|
|
|
FIGURE 3
|
FIGURE 4
|
-
Push the pins out with a modified Allen wrench, or
a modified spring hook. See Figures 5 & 6
-
Separate the two halves. See Figure 7
-
Remove the drum end cap and screw. See Figure 8
FIGURE 5 |
FIGURE 6 |
|
|
FIGURE 7 |
FIGURE 8 |
-
Remove the drum. See Figure 9. Note the curved
plastic piece around the drum. Because of this piece, the drum cannot be
removed before the two halves are separated.
-
Remove the PCR and clean with your standard PCR
cleaner. We have been using Nu-Finish for years with out any problems. See
Figure 10
-
Remove the Wiper Blade, the blade is the same as
used in the HP-1200. See Figure 11
-
Clean out the waste toner.
-
Coat the wiper blade with your preferred
lubricant, and re-install. See Figure 12
FIGURE 9 |
FIGURE 10 |
|
|
FIGURE 11 |
FIGURE 12 |
-
Re-install the cleaned PCR. Note that a new OEM
PCR has a small amount of conductive grease on the black (contact) side
and what appears to be white lithium grease on the other. See Figures 13 &
14
-
Re-Install the OPC Drum, end cap, and screw. Slide
the hub end onto the drum axle and drop in place. This axle pin is very
hard to remove, so this is actually the best way. See Figures 15 & 16
FIGURE 13 |
FIGURE 14 |
|
|
FIGURE 15 |
FIGURE 16 |
-
Remove the right side toner hopper end cap. See
Figure 17
-
Remove the white gears as shown in Figures 18 &
19. These gears are loose and will fall off if not removed.
-
Remove the left side end cap. This is the side
that houses the Magnetic roller contacts and fill plug. See Figure’s 20 &
21.
FIGURE 17 |
FIGURE 18 |
|
|
FIGURE 19 |
FIGURE 20 |
-
Remove the magnetic roller assembly. Although not
necessary, I find it easier to keep the magnetic roller gears and spacer hubs
all together. See Figure 22
-
If you are going to replace the magnetic roller
sleeve, the contact plate must be removed. It is held in place by a small
metal tab that presses against the stationary magnet core. Carefully pry
up the tab with a small jeweler’s screwdriver, and remove the plate. Press
in from the metal hub side with a small screwdriver to drive the plastic
hub out. Make sure when you install the stationary magnet into the new
sleeve, that you turn the magnet until it seats in the sleeve. The metal
hub and the magnet are keyed. See Figures 23, 24, and 25.
FIGURE 21 |
FIGURE 22 |
|
|
FIGURE 23 |
FIGURE 24 |
-
Remove the DR. Blade. See Figure 26.
-
Fill through the Mag roller opening with 150g of
1200 toner for the “A” cartridge, 240g for the “X”. You can fill through
the fill hole but unless a seal is installed, you must hold the magnetic
roller assy. in place, a very tricky thing to do. See Figure 27
-
If you are going to seal the cartridge, it should
be placed on top of the silver areas shown in Figure 28. The seal tab fits
through the right side of the cartridge (fill plug side). Figure 29 shows
both the seal exit slot and the fill plug. Figure 30 is a close up
of the seal exit slot. Figure 31 shows the seal and exit port seal
installed. Note that it has a rubber gasket that seals off the opening.
This port seal must be removed before inserting a seal. Make sure it is
put back or the cartridge will leak after the seal has been removed!
FIGURE 25 |
FIGURE 26 |
|
|
FIGURE 27 |
FIGURE 28 |
|
|
FIGURE 29 |
FIGURE 30 |
|
|
FIGURE 31 |
|
-
Re-install the doctor Blade.
-
Re-assemble the toner hopper section. Place the
Mag. Roller Assy. in the hopper, and install the left end cap first. Align
the keyed magnet into the keyed slot. See Figure 32
-
Install the right side gears, end cap and screw.
Align the two posts on the end cap, and the two holes in the white spacer.
If all is correct, the end cap should fir flush with the hopper. See
Figures 33 & 34
FIGURE 32 |
FIGURE 33 |
|
|
FIGURE 34 |
|
-
Place the two halves together, make sure that the
two springs are aligned, and insert the two pins. Make sure that the pins
are slightly pushed in so that they do not interfere with installing the
cartridge in the printer. See Figures 35, 36, and 37.
-
Install the drum cover; make sure the spring is
situated correctly. See Figure 38
FIGURE 35 |
FIGURE 36 |
|
|
FIGURE 37 |
FIGURE 38 |
Back grounding: (Gray Streaks) This is
usually caused by a dirty/worn out PCR, or a worn out wiper blade.
Light Print: Can be caused by a
dirty/worn Magnetic Roller or worn doctor blade.
Solid Black Pages: Bad drum ground
contact. Probably from the drum axle shaft to the contact gear inside the
drum.
Perfectly straight thin black lines
down the page: Scratched drum.
Black dots that repeat every 3": Bad
drum, or something is stuck to the drum surface.
Dark black Horizontal lines: Are
usually caused by either a bad PCR connection, a pin hole in the PCR, or a
pin hole in the drum. These lines normally run about 1/8” thick and can show
as few as 4 times/page and as many as 12 times/page.
“Tire Tracks” on the right edge of the
page are caused by a worn out drum. (Tire Tracks are what we call a vertical
shaded area with lines in it that look like tire tread marks in the sand.
This normally happens to OEM drums.
Half the page prints, the other half is blank:
The cartridge pin on the blank side is most likely not installed
correctly. Remove the pin and re-install making sure that the pin is
inserted into both halves
Two pages are available from the front panel of the
printer, the Demo Page, and the Configuration Page.
To run the Demo Page, make sure that the ready light
is on, and briefly press the GO button. The Demo Page will print out.
To run the Configuration Page, make sure that the
ready light is on and press the GO button for 5 seconds. When the GO light
turns on, release the button. Two pages with complete printer info including
the page count as well as a supplies status page will print out.
To run the Cleaning Page, make sure that the ready
light is on and press the GO button for 10 seconds. When all three lights
turn on, release the button.
The cleaning process takes about 2 minutes. The
cleaning page will stop periodically during the cleaning process. Do not
turn the printer off until the process has finished.
As with the 1200 and
1300, these machines do not have a display panel. All the error codes
consist of different pattern of the three lights.
Bottom small light
blinking: Cartridge door open, no print cartridge installed, or
there is a paper jam.
All three lights
on: Fatal error; turn the printer off, and unplug it for 5 minutes.
If the error still exists, the printer has a major problem. There is no
information yet on what these problems may be. (The service manual has not
been released yet).
All three lights blinking: Accessory
error; Remove the DIMMs and replace as necessary.
All three lights cycle in sequence: The
printer is initializing, the cleaning page is being run, or a job cancel
command has been sent.
|